Analisis Perbandingan Nilai NTID OAR Sigmoid Colon, CI, dan HI pada Teknik 3D-CRT dan IMRT terhadap Kanker Rektum

Authors

  • Nurhikma Aris Universitas Hasanuddin
  • Syamsir Dewang Universitas Hasanuddin
  • Saleha Instalasi Radioterapi, Rumah Sakit TK II Pelamonia, Makassar
  • Sri Dewi Astuty Universitas Hasanuddin
  • Ayu Hardianti Pratiwi Universitas Hasanuddin
  • Ajeng Anggreny Ibrahim Universitas Hasanuddin

DOI:

https://doi.org/10.24252/jft.v12i2.59407

Keywords:

3D-CRT, IMRT, NTID, Rectum Cancer, Sigmoid Colon

Abstract

A study was conducted to analyze the comparison of Normal Tissue Integral Dose (NTID) in the sigmoid colon OAR, Conformity Index (CI), and Homogeneity Index (HI) in rectal cancer cases using 3D-CRT and IMRT techniques based on data from the Treatment Planning System (TPS) for five rectum cancer patients. The objective of this study was to compare the NTID values of the sigmoid colon OAR, as well as CI and HI, between the 3D-CRT and IMRT techniques. The research was conducted using data from five rectum cancer patients treated at TK II Pelamonia Hospital, where each patient received a total radiation dose of 50 Gy, delivered in 25 fractions of 2 Gy per session. Data were collected through analysis of the Dose Volume Histogram (DVH), which included the volume of the tumor receiving 95% of the prescribed dose, total tumor volume, radiation doses at 2%, 50%, and 98% of the target volume, mean dose, and the volume of the Organ at Risk (OAR). The results showed that the NTID values for the sigmoid colon OAR ranged from 0.87 to 21.11 Gy for the 3D-CRT technique, and from 2,7 to 9,86 Gy for the IMRT technique. The CI values for both techniques ranged from 0.95 to 0.99, while the HI values were between 0,07 and 0,18 for 3D-CRT, and 0,08 to 0,13 for IMRT none of which exceeded the value of 1, which indicates that the isodose curve at the prescribed dose is able to accurately and completely encompass the entire Planning Target Volume (PTV).

Downloads

Download data is not yet available.

References

[1] GLOBOCAN, “International Agencyfor Research on Cancer,” World Health Organization.[Online].Available:https://gco.iarc.fr/today/en/dataviz/pie?mode=cancer&group_populations=1

[2] A. T. Hawkins et al., “The American Society of Colon and Rectal Surgeons,” Clin. Pract. Guidel., vol. 65, no. 2, pp. 148–177, 2022, doi: 10.1097/DCR.0000000000002323.

[3] D. Retnaningsih, E. Ferari, and R. Winarti, “PENGALAMAN PERAWATAN KANKER KOLON STADIUM AKHIR: CASE STUDY,” J. SURYA MUDA, vol. 4, no. 1, pp. 37–49, 2022.

[4] M. Husni, M. A. Shafii, R. Adrial, and M. Ilyas, “Analisis Perbandingan Nilai Conformity Index dan Homogeneity Index pada Teknik 3D-CRT dan IMRT pada Kasus Kanker Payudara Berdasarkan Hasil TPS di RS UNAND,” J. Fis. Unand, vol. 10, no. 4, pp. 511–517, 2021.

[5] D. Agustini, A. Winanda, and L. Prananto, “Jurnal Mahasiswa dan Penelitian Kesehatan Penatalaksanaan Radioterapi pada Kanker Payudara dengan Teknik IMRT Di Instalasi Radioterapi Rumah Sakit Gading Pluit,” JUMANTIK J. Mhs. dan Penelit. Kesehat., vol. 8, no. 1, pp. 36–39, 2021.

[6] Y. E. Daniartie, P. S. Wardani, D. R. P. S. Putri, R. J. Stevenly, and S. Suryaningsih, “Analisis Treatment Planning System dengan Menggunakan Teknik Box dan Teknik Antero Posterior-Postero Anterior pada Kasus Kanker Serviks,” Progress. Phys. J., vol. 3, no. 1, p. 118, 2022, doi: 10.30872/ppj.v3i1.873.

[7] O. Febrietri, D. Milvita, and F. Diyona, “Analisis Dosis Radiasi Paru-Paru Pasien Kanker Payudara dengan Teknik Three-Dimensional Conformal Radiation Therapy ( 3D-CRT ) Berdasarkan Grafik Dose Volume Histogram ( DVH ),” J. Fis. Unand, vol. 9, no. 1, pp. 110–117, 2020.

[8] G. Novinda, “Evaluasi Dosis Foton Pada Pasien Kanker Rektum Dengan Teknik 3Dcrt Dan Imrt,” J. Pendidik. Fis. dan Ter., vol. 7, no. 1, pp. 51–57, 2024, doi: 10.46918/karst.v7i1.2221.

[9] Putra, Ni Putu Rita Jeniyanthi, and Ngakan Putu Daksa Ganapati, “Analisis Perhitungan Nilai Rata-Rata Pergeseran Verifikasi Geometri Menggunakan EPID Pada Pasien Kanker Payudara Di Sub Instalasi Radioterapi RSUP Prof. Dr. I.G.N.G Ngoerah,” J. Anestesi, vol. 2, no. 1, pp. 88–100, 2023, doi: 10.59680/anestesi.v2i1.759.

[10] F. Istiqomah, M. Irsal, S. G. Sutoro, G. Winarno, and I. G. K. Wardana, “Evaluation Target Volume and Distribution Organ at Risk in Rectal Cancer Using 3D-CRT Technique Based on QUANTEC,” Int. J. Sci. Res. Sci. Technol., pp. 173–180, 2024.

[11] I. P. Riani et al., “Analisis Parameter Perencanaan dan Evaluasi Kurva Dose Volume Histogram Pasien Kanker Glioblastoma Berdasarkan Treatment Planning System Rumah Sakit Universitas Andalas , Padang , Indonesia,” J. Fis. Unand, vol. 13, no. 5, pp. 617–623, 2024.

[12] ICRU, “The International Commission on Radiation Units and Measurements,” J. ICRU Rep. 83, vol. 10, no. 1, 2010, doi: 10.1093/jicru/ndq001.

[13] Y. Asri, G. N. Sutapa, I. W. B. Sudarsana, and R. Irhas, “Perbandingan Radiasi Kanker Serviks Pada Organ Bladder Dengan Radioterapi LINAC Energi 10 MV Menggunakan Teknik 3DCRT dan IMRT Di RSUP Sanglah Denpasar Comparison of Cervical Cancer Radiation in Bladder Organs with 10 MV LINAC Energy Radiotherapy Using 3D,” Bul. Fis., vol. 19, no. 2, pp. 98–105, 2023.

[14] ICRU, “International Commission on Radiation Units and Measurements. Prescribing, recording, and reporting electron beam therapy.,” 1999.

[15] M. S. Fazeli and M. R. Keramati, “Rectal cancer: A review,” Med. J. Islam. Repub. Iran, vol. 29, pp. 1–23, 2015.

[16] E. Kimpe et al., “Quantifying societal burden of radiation-induced small bowel toxicity in patients with rectal cancer,” Front. Oncol., vol. 14, no. July, 2024, doi: 10.3389/fonc.2024.1340081.

[17] S. Dashnamoorthy, E. Jeyasingh, and I. Ahmed, “Comparison of normal tissue integral dose with monitor units from 3DCRT, IMRT, and Rapid Arc treatment planning methods for head and neck, pelvic and thoracic cancer sites,” Int. J. Radiat. Res., vol. 22, no. 4, pp. 1019–1025, 2024, doi: 10.61186/ijrr.22.4.1019.

[18] R. Ricotti et al., “Dosimetric effect of variable rectum and sigmoid colon filling during carbon ion radiotherapy to sacral chordoma,” Phys. Medica, vol. 90, no. August, pp. 123–133, 2021, doi: 10.1016/j.ejmp.2021.09.012.

[19] S. Yani, “Analisis Kurva Dose Volume Histogram (DVH) pada Teknik 3D Konformal dengan Metode Monte Carlo,” Positron, vol. 11, no. 1, p. 19, 2021, doi: 10.26418/positron.v11i1.44052.

Downloads

Published

2026-01-02

How to Cite

Aris, N., Syamsir Dewang, Saleha, Sri Dewi Astuty, Ayu Hardianti Pratiwi, & Ajeng Anggreny Ibrahim. (2026). Analisis Perbandingan Nilai NTID OAR Sigmoid Colon, CI, dan HI pada Teknik 3D-CRT dan IMRT terhadap Kanker Rektum . JFT: Jurnal Fisika Dan Terapannya, 12(2), 231–243. https://doi.org/10.24252/jft.v12i2.59407

Issue

Section

Artikel