One of the parameters of CT-Scan that is of particular concern is the radiation dose. Receipt of excessive radiation dose in patients will cause cancer. It is necessary to minimize the radiation dose received by patients in each examination by comparing the optimization index called Diagnostic Reference Level (DRL). This study aims to determine the local DRL value on CT-Scan at RSIY PDHI and compare and analyze with the national DRL value set by BAPETEN. This research is quantitative study with an experimental approach that aims to analyze the CTDIvol and DLP values on CT-Scan at RSIY PDHI. The DRL value is determined by determining the 75thpercentile value of CTDIvol and DLP values in CT-Scan examinations. This study was conducted on head examination in 156 patients without contrast and 2 patients with contrast, abdominal examination in 54 patients without contrast and 7 patients with contras, and thorax examination in 2 patients without contrast and 1 patient with contrast. In this study, the local DRL value of RSIY PDHI was obtained, with CTDIvol values in head, abdomen, and thorax examinations without contrast of 55,1; 12,5; and 5,4 mGy, respectively. And examination without contrast obtained values of 38,4; 10,2; and 4,47 mGy respectively. The DLP values in head, abdomen, and thorax examinations without contrast are 1122; 601; and 150 mGy.cm respectively. Examination with contrast obtained respectively 781; 479; and 151 mGy.cm. The DRL value obtained is categorized as safe because the local DRL value of RSIY PDHI has a lower value than the national DRL value set by BAPETEN.

Downloads

Download data is not yet available.

References

Annisah, R. (2022). Penentuan Nilai Diagnostic Reference Level CT-Scan di Rumah Sakit Universitas Tanjungpura Pontianak. PRISMA FISIKA, 10(3), 387–391.

BAPETEN. (2021). Keputusan Kepala Badan Pengawas Tenaga Nuklir Nomor:12 11/K/V/2021 Tentang Penetapan Nilai Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level) Untuk Modalitas Sinar-X CT Scan dan Radiograafi Umum.

Brilianti, A. (2022). Kajian Sistem Perhitungan Typical Dose Pesawat X-Ray General Purpose Berbasis Usia dan Objek Pemeriksaan di RS Haji Makassar.

Duandini, E., Etika, E. A., Nurulita, S. F., & Hidayanto, E. (2021). Analisis Perbandingan Diagnostoc Reference Level (DRL) Modalitas CT Scan sebagai Upaya Optimasi Proteksi dan Keselamatan Radiasi di Berbagai Negara. Berkala Fisika, 24, 100–108.

Latifah, R., Jannah Z, N., Nurdin, D. Z. I., & P, B. (2019). Determination of Local Diagnostic Reference Level (LDL) Pediatric Patients on CT Head Examination Based on Size-Specific Dose Estimates (SSDE) Values. Journal Of Vocational Health Studies, 02, 127–133.

Masuku, R. S. (2023). Analisis Nilai Computer Tomography Dose Index (CTDI) dan Dose Length Product (DLP) pada Pemeriksaan Multislice Computed Tomography (MSCT) Trauma Kepala Dewasa di Instalasi Radiologi Rumah Sakit Balimed Denpasar, Bali. Nautical: Jurnal Ilmiah Multidisiplin, 1.

Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., McGale, P., Cain, T. M., Dowty, J. G., Bickerstaffe, A. C., & Darby, S. C. (2013). Cancer Risk in 680 000 People Exposed to Computed Tomography Scans in Childhood or Adolescence: Data Linkage Study of 11 million Australians. BMJ (Online), 346(7910). https://doi.org/10.1136/bmj.f2360

Muhamad, W. K. I., Sutapa, G. N., Kasmawan, I. G. A., & Irhas, R. (2022). Analisis Pengaruh Field of View (FOV) Terhadap Kualitas Citra Pesawat CT Scan di RSU Bali Jimbaran. Desember 2022, 6(2), 383–389. http://e-journal.hamzanwadi.ac.id/index.php/kpj/index

Radaideh, K., Al-Radaideh, A., Ramli, R. M., Saleh, A., & Alshayeb, R. (2023). Establishment of National Diagnostic Dose Reference Levels (DRLs) for Routine Computed Tomography Examinations in Jordan. Polish Journal of Medical Physics and Engineering, 29(1), 26–34. https://doi.org/10.2478/pjmpe-2023-0003

Sofiana, L., Noor, J. A. E., & Normahayu, I. (2013). Estimasi Dosis Efektif pada Pemeriksaan Multi Slice CT-Scan Kepala dan Abdomen berdasarkan Rekomendasi ICRP 103. Brawijaya Physic Student Journal, 1(1).

Syahmitalia, V., Arifin, Z., & Rusmanto. (2021). Analisis Nilai Diagnostic Reference Level (DRL) Dewasa Pemeriksaan Lumbal Spine Anterior-Posterior (AP) dan Lateral (LAT) Modalitas Radiografi Umum di Indonesia Berdasarkan Database Dosis Pasien Si-INTAN. Jurnal Pengawasan Tenaga Nuklir, 1(1), 47–51. https://doi.org/10.53862/jupeten.v1i1.010

Published

2025-07-09

How to Cite

Mas’uul, A. R., Kanayanaquita, & Handayani, N. (2025). IMPLEMENTATION OF LOCAL DIAGNOSTIC REFRENCES LEVEL (DRL) ON CT-SCAN AT RSI YOGYAKARTA PDHI. Jurnal Kesehatan, 18(1), 1–10. https://doi.org/10.24252/kesehatan.v18i1.45016