Perbandingan Stabilitas Bahan dan Kualitas Citra Grayscale pada Phantom Ultrasonography (USG) Berbasis Agar dan Oli

Authors

  • Kusma Dwi Yuristika Sekolah Tinggi Ilmu Kesehatan Semarang
  • Imam Tri Harsoyo Sekolah Tinggi Ilmu Kesehatan Semarang
  • Pramesti Kusumaningtyas Sekolah Tinggi Ilmu Kesehatan Semarang

DOI:

https://doi.org/10.24252/jft.v12i2.57188

Keywords:

Agar, Grayscale, oil, phantom, Ultranography (USG)

Abstract

This study aims to compare the stability of materials and grayscale image quality of agar and oil-based ultrasonography (USG) phantoms. The method used includes making two types of phantoms with the same object, then imaging using a MINDRAY brand Ultrasography (USG) device type DP-10. Grayscale data was analyzed by calculating the average, standard deviation, and visual evaluation based on homogeneity, contrast, noise, and edge sharpness. The results showed that both phantoms had grayscale values ​​that were still within the tolerance range of ±10% of the average, indicating the stability of wave propagation at an acceptable depth. However, the oil phantom showed a higher average intensity value of 9.838 cm and a lower standard deviation of 0.152053, compared to agar 9.584 cm and a standard deviation of 0.202. The oil phantom image appeared more homogeneous, sharp, and had minimal noise compared to the agar phantom. Thus, the oil-based phantom is considered superior in producing stable and representative grayscale image quality, and is more durable than agar

Downloads

Download data is not yet available.

References

[1] C. F. R. Putri, G. Maslebu, and A. Setiawan, “Analisis Densitas Larutan Berbasis Citra Phantom Agar dalam Kendali Mutu USG,” Positron, vol. 11, no. 1, p. 26, 2021, doi: 10.26418/positron.v11i1.44404.

[2] D. Pangestuti, G. Maslebu, and S. Trihandaru, “Perancangan Pengukuran Akurasi Jarak Menggunakan Phantom Silicone Pada Kontrol Kualitas Ultrasonografi dengan Teknik Komputasi,” J. Sains dan Edukasi Sains, vol. 2, no. 1, pp. 36–41, 2019, doi: 10.24246/juses.v2i1p36-41.

[3] N. F. Suryaningsih, B. S. Nirwana, P. Wahyu Wigati, and H. Saidah, “Hubungan Tingkat Pengetahuan Ibu Hamil Tentang Ultrasonografi Dalam Pemeriksaan Kehamilan Dengan Perilaku Pemanfaatan Ultrasonografi,” J. Mhs. Kesehat., vol. 4, no. 1, pp. 1–10, 2023, doi: 10.30737/jumakes.v4i1.3505.

[4] Yenni and A. T. Angka, “Hubungan Tingkat Pengetahuan Ibu Hamil Tentang Pemanfaatan Usg Di Klinik Wijaya Kusuma Makassar,” Public Heal. Med. J., vol. 2(1), 22–3, pp. 22–31, 2024.

[5] A. Suzuki et al., “Oil Gel-Based Phantom for Evaluating Quantitative Accuracy of Speed of Sound Measured in Ultrasound Computed Tomography,” Ultrasound Med. Biol., vol. 45, no. 9, pp. 2554–2567, 2019, doi: 10.1016/j.ultrasmedbio.2019.05.011.

[6] Y. Wang et al., “Fabrication of SEBS Block Copolymer-Based Ultrasound Phantom Containing Mimic Tumors for Ultrasound-Guided Needle Biopsy Training,” Ultrasound Med. Biol., vol. 48, no. 6, pp. 1143–1150, 2022, doi: 10.1016/j.ultrasmedbio.2022.02.020.

[7] T. Z. Pavan and M. Evertsson, “Oil-Based Gel Phantoms and the Speed of Sound,” Ultrasound Med. Biol., vol. 46, no. 11, pp. 3170–3171, 2020, doi: 10.1016/j.ultrasmedbio.2020.07.011.

[8] A. Scorza, F. Orsini, and S. Andrea Sciuto, “Use of phantoms and test objects for local dynamic range evaluation in medical ultrasounds: A preliminary study,” I2MTC 2017 - 2017 IEEE Int. Instrum. Meas. Technol. Conf. Proc., 2017, doi: 10.1109/I2MTC.2017.7969844.

[9] F. Noo, K. Hahn, H. C. Davidson, U. Rassner, and M. E. Heilbrun, “Influence of the grayscale on phantom-based image quality assessment in x-ray computed tomography,” Med. Imaging 2015 Image Perception, Obs. Performance, Technol. Assess., vol. 9416, p. 94160G, 2015, doi: 10.1117/12.2082914.

[10] C. Noor Santi, “Mengubah Citra Berwarna Menjadi Gray Scale dan Citra biner Rina,” Teknol. Inf. Din., vol. 16, no. 1, pp. 14–19, 2011.

[11] A. Prasetio, “Citra Digital Dan Algoritma Penerapannya,” pp. 4–16, 2021, [Online]. Available: http://dx.doi.org/10.31237/osf.io/7amr8

[12] M. S. Ummah, “Perbaikan Kualitas Citra Grayscale Dengan Metode Median Filter,” Sustain., vol. 11, no. 1, pp. 1–14, 2019, [Online]. Available: http://scioteca.caf.com/bitstream/handle/123456789/1091/RED2017-Eng-8ene.pdf?sequence=12&isAllowed=y%0Ahttp://dx.doi.org/10.1016/j.regsciurbeco.2008.06.005%0Ahttps://www.researchgate.net/publication/305320484_SISTEM_PEMBETUNGAN_TERPUSAT_STRATEGI_MELESTARI

[13] L. C. Cabrelli, F. W. Grillo, A. A. O. Carneiro, and T. Z. Pavan, “Copolymer-in-oil tissue-mimicking material with tunable acoustic properties,” IEEE Int. Ultrason. Symp. IUS, vol. 2016-Novem, pp. 8–11, 2016, doi: 10.1109/ULTSYM.2016.7728859.

[14] P. Chen et al., “Acoustic characterization of tissue-mimicking materials for ultrasound perfusion imaging research,” Ultrasound Med. Biol., vol. 48, no. 1, pp. 124–142, 2022, doi: 10.1016/j.ultrasmedbio.2021.09.004.

[15] A. Pratikno, A. Prastiwi, and S. Ramahwati, “Ragam Simpangan Baku serta Cara Menghitung Ragam Simpangan Baku,” pp. 5–7, Mar. 2020, doi: 10.31219/osf.io/q9umh.

Downloads

Published

2026-01-13

How to Cite

Kusma Dwi Yuristika, Imam Tri Harsoyo, & Pramesti Kusumaningtyas. (2026). Perbandingan Stabilitas Bahan dan Kualitas Citra Grayscale pada Phantom Ultrasonography (USG) Berbasis Agar dan Oli. JFT: Jurnal Fisika Dan Terapannya, 12(2), 244–251. https://doi.org/10.24252/jft.v12i2.57188

Issue

Section

Artikel