Analisis Kontur Isodosis Radiasi Sinar-X di Instalasi Radiologi Rumah Sakit Umum Daerah Labuang Baji Makassar
DOI:
https://doi.org/10.24252/jft.v12i1.57807Keywords:
Dose Rate, Isodose Contours, Radiation Dose, Surfer Software, Survey MeterAbstract
Isodosis contour analysis using surfer type 21 software has been conducted in the radiology installation of Labuang Baji Hospital Makassar to determine the safest distance for radiology medical personnel while in the X-ray aircraft area. Measurements were carried out before and during exposure to a water phantom using an X-ray aircraft with a surveymeter. Radiation exposure rates were measured at 8 track locations in the X-ray aircraft room, consisting of 16 points located on the track (A, B, C, D, E, F, G, H) at 1 m and 1.5 m heights. The processed data showed that the highest radiation exposure dose was in the E-1 track (in front of the X-ray plane), which was 0.001791 mSv with a radiation dose exposure rate of 43.320 mSv/hour for a height of 1 m and 0.001228 mSv in the A-1 track for a height of 1.5 m with a radiation dose exposure rate of 29.7997 mSv/hour. The isodose contours also show variations in the number of passes and different colors for each radiation exposure dose value. The findings of this study indicate that the radiation exposure dose is 0 mSv at a distance of more than 2 m from the X-ray plane, so the radiologist is within safe limits to perform radiodiagnostic procedures.
Downloads
References
[1] I. of M. Staff, K.-L. D. Gottfried, and G. Penn, Radiation in Medicine: A Need for Regulatory Reform. Washington: National Academies Press, 1996.
[2] K. S. Da Poça, “Use of Ionizing Radiation in the Health Sector,” BJSTR, vol. 29, no. 5, Sep. 2020, doi: 10.26717/BJSTR.2020.29.004876.
[3] T. Shelkovenko, S. Pikuz, and D. Hammer, “X-Pinches as Broadband Sources of X-Rays for Radiography,” JBiSE, vol. 08, no. 11, pp. 747–755, 2015, doi: 10.4236/jbise.2015.811071.
[4] J. R. Parikh et al., “Potential Radiation-Related Effects on Radiologists,” American Journal of Roentgenology, vol. 208, no. 3, pp. 595–602, Mar. 2017, doi: 10.2214/AJR.16.17212.
[5] J. Simanjuntak, A. Camelia, and I. G. Purba, “Penerapan Keselamatan Radiasi Pada Instalasi Radiologi Di Rumah Sakit Khusus (RSK) Paru Provinsi Sumatera Selatan Tahun 2013,” Jurnal Ilmu Kesehatan Masyarakat, vol.04, no.03, pp. 245-253, Nov.2013, https://ejournal.fkm.unsri.ac.id/index.php/jikm/article/view/300.
[6] D. Y. Breitkreutz, M. D. Weil, and M. Bazalova-Carter, “External beam radiation therapy with kilovoltage X-rays,” Physica Medica, vol. 79, pp. 103–112, Nov. 2020, doi: 10.1016/j.ejmp.2020.11.001.
[7] A. Allan, “X-ray Imaging Advancements and Applications in Medical Diagnosis,” 2023, 28-June-2023, 15(5).112 -114. DOI: 10.37532/1755-5191.2023.
[8] IAEA (International Atomic Energy Agency), “International Nuclear Security Advisory Service (INSServ) Guidelines,” VIENNA, 2019.
[9] J. H. Kim, “Three principles for radiation safety: time, distance, and shielding,” Korean J Pain, vol. 31, no. 3, pp. 145–146, Jul. 2018, doi: 10.3344/kjp.2018.31.3.145.
[10] S. S. Alshowiman, “Principles of Radiation Protection for Patients and Medical Staff,” BJSTR, vol. 54, no. 2, Dec. 2023, doi: 10.26717/BJSTR.2023.54.008520.
[11] W. Dian Kusuma, S. Rurie Ratna, and G. Rellyca Sola, “Radiation Protection Efforts in Restricting Exposure to Scattered Radiation Based on Room Analysis,” Int J Radiol Imaging Technol, vol. 8, no. 2, Dec. 2022, doi: 10.23937/2572-3235.1510097.
[12] S. Choudhary, “Deterministic and Stochastic Effects of Radiation,” CTOIJ, vol. 12, no. 2, Oct. 2018, doi: 10.19080/CTOIJ.2018.12.555834.
[13] J. Sabol and B. Šesták, “Quantification Of The Risk-Reflecting Stochastic and Deterministic Radiation Effects,” in RAD Conference Proceedings, RAD Association, 2017. doi: 10.21175/RadProc.2017.22.
[14] S. Park, M. Kim, and J. H. Kim, “Radiation safety for pain physicians: principles and recommendations,” Korean J Pain, vol. 35, no. 2, pp. 129–139, Apr. 2022, doi: 10.3344/kjp.2022.35.2.129.
[15] L. Brateman, “The AAPM/RSNA Physics Tutorial for Residents”, Imaging and Therapeutic Technology, vol.09, no.4, pp.1037-1055, March 2019. https://www.researchgate.net/publication/331717578
[16] K. Yamamoto et al., “Basic Performance Evaluation of a Radiation Survey Meter That Uses a Plastic-Scintillation Sensor,” Sensors, vol. 24, no. 10, p. 2973, May 2024, doi: 10.3390/s24102973.
[17] P. Purwantiningsih, “Analisis Sebaran Dosis Paparan Radiasi Pesawat C-Arm Terhadap Jarak Pada Ruangan Operasi,” SAINTEK, vol. 9, no. 2, p. 183, Dec. 2018, doi: 10.31958/js.v9i2.1152.
[18] F. Tulfala and Kasman, “Analisis Kontur Isodosis Paparan Radiasi Sinar-X di Instalasi Radiologi UPT Rumah Sakit Umum Daerah Madani Palu,” Gravitasi, vol. 19, no. 1, pp. 20–23, Jun. 2020, doi: 10.22487/gravitasi.v19i1.15105.
[19] M. I. H. Putra, R. Adrial, and A. O. S, “Analisis Kontur Isodosis Radiasi pada Pesawat Sinar-X di Instalasi Radiologi Rumah Sakit Universitas Andalas,” JFU, vol. 12, no. 2, pp. 329–334, Apr. 2023, doi: 10.25077/jfu.12.2.328-333.2023.
[20] M. Alipio, E. P. Somontan, P. E. Reyes, and G. M. Lantajo, “Development of an X-ray Shielding Material Based on Eggshells and Crab Shells,” 2022.
[21] N. P. Dewi, N. L. P. Trisnawati, and M. Iffah, “Laju Paparan Radiasi Sinar-X pada Dinding Laboratorium Diagnostik ATRO Bali,” BF, vol. 24, no. 1, p. 49, Nov. 2021, doi: 10.24843/BF.2023.v24.i01.p07.
[22] Y. A. Noya, S. R. Loupatty, G. D. Manuputty, and E. S. Ratuluhain, “Pelatihan Pembuatan Peta Kontur Tiga Dimensi Dengan Menggunakan Program Surfer,” JHI, vol. 3, no. 2, pp. 86–93, Oct. 2023, doi: 10.55984/hirono.v3i2.141.
[23] S. Rosidah and F. Felayani, “Effect Of Heel Effect Anode On Image Homogeneity Based On X-Ray Collimation Light Beam Area,” vol. 13, no. 01, 2022.
[24] S. Prabhu, D. K. Naveen, S. Bangera, and B. Subrahmanya Bhat, “Production of X-RAYS using X-RAY Tube,” J. Phys.: Conf. Ser., vol. 1712, no. 1, p. 012036, Dec. 2020, doi: 10.1088/1742-6596/1712/1/012036.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Sitti Normawati, Jumardin Jumardin; Resky Ulandari, Hidayat Dg Manarang

This work is licensed under a Creative Commons Attribution 4.0 International License.