Evaluasi Air dan Oli sebagai Material Dasar Phantom Anechoic untuk Aplikasi Ultrasonography (USG)
Kata Kunci:
phantom anechoic, base material, ultrasonography, oil, waterAbstrak
The increasing demand for ultrasonography (USG) phantoms for training and equipment calibration highlights the need for effective and affordable local alternatives. This study investigates two base materials water and oilas anechoic phantom media through a laboratory-based experimental approach. Phantoms were constructed by placing two test objects a gasoline filled straw and a piece of Styrofoam into separate containers filled with each medium, then scanned using the Mindray DP-10 ultrasound device. Measurements of object diameter and depth were conducted five times to assess precision and image quality. Numerical data and visual outputs were analyzed comparatively to evaluate acoustic characteristics, image clarity, noise level, and stability. The findings reveal notable differences in imaging performance between the two materials, reflecting the influence of acoustic impedance and viscosity on phantom effectiveness in USG applications.
Unduhan
Referensi
[1] N. M. Al-Munawar, C. FRW, and A. Y. Jufan, “Peran Ultrasonografi dalam Kegawatdaruratan,” J. Komplikasi Anestesi, vol. 2, no. 2, pp. 85–94, 2023, doi: 10.22146/jka.v2i2.7212.
[2] Lady Tioro Coilal, Legina Anggraeni, and Irwanti Gustina, “Gambaran Tingkat Pengetahuan Ibu Hamil Tentang Manfaat Ultrasonografi (Usg) Dalam Pemeriksaan Kehamilan,” Binawan Student J., vol. 2, no. 2, pp. 242–245, 2020, doi: 10.54771/bsj.v2i2.125.
[3] N. A. Mappaware et al., “Ultrasonografi Obstetri Dalam Prespektif Medis, Kaidah Bioetika Dan Islam,” Wal’afiat Hosp. J., vol. 1, no. 1, pp. 1–14, 2020, doi: 10.33096/whj.v1i1.2.
[4] J. I. W. MZ et al., “Frekuensi Pemeriksaan Ultrasonografi (USG) pada Pasien Antenatal Care (ANC),” Fakumi Med. J. J. Mhs. Kedokt., vol. 1, no. 3, pp. 161–169, 2022, doi: 10.33096/fmj.v1i3.60.
[5] G. Vara, A. Rustici, A. Sechi, C. Mosconi, V. Lucidi, and R. Golfieri, “Texture analysis on ultrasound: The effect of time gain compensation on histogram metrics and gray-level matrices,” J. Med. Phys., vol. 45, no. 4, pp. 249–255, 2020, doi: 10.4103/jmp.JMP_82_20.
[6] V. Tsapaki, I. A. Tsalafoutas, S. S. Triantopoulou, and C. Triantopoulou, “Development and implementation of a quality control protocol for B-mode ultrasound equipment,” J. Ultrasound, vol. 25, no. 2, pp. 155–165, 2022, doi: 10.1007/s40477-021-00579-7.
[7] P. J. Pardosi, M. A. Primasyukra, S. Ulina, and K. Abdillah, “Analisa Pemeliharaan Preventif Alat Ultrasonograph (Usg) Siemens Aquson-X300 Di Rumah Sakit Universitas Sumatera Utara,” J. Mutiara Elektromedik, vol. 8, no. 1, pp. 29–36, 2024, doi: 10.51544/elektromedik.v8i1.5300.
[8] N. Iqeilan, A. Aly, S. Al Mohannadi, and H. Al Naemi, “Quality Control Program in Medical Ultrasound at Hamad Medical Corporation: Current Status,” Eur. J. Med. Heal. Sci., vol. 4, no. 2, pp. 23–26, 2022, doi: 10.24018/ejmed.2022.4.2.995.
[9] E. Sassaroli, A. Scorza, C. Crake, S. A. Sciuto, and M. A. Park, “Breast ultrasound technology and performance evaluation of ultrasound equipment: B-mode,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 64, no. 1, pp. 192–205, 2017, doi: 10.1109/TUFFC.2016.2619622.
[10] H. Grazhdani et al., “Quality assurance of ultrasound systems: current status and review of literature,” J. Ultrasound, vol. 21, no. 3, pp. 173–182, 2018, doi: 10.1007/s40477-018-0304-7.
[11] Dyah Ayu Permata Sari and Sumadi, “Analisis Kelayakan Pengembangan Usaha Kalibrasi Pt. Indraloka Kabupaten Sukoharjo,” Semin. Nas. Pariwisata dan Kewirausahaan, vol. 2, pp. 209–216, 2023, doi: 10.36441/snpk.vol2.2023.119.
[12] C. F. R. Putri, G. Maslebu, and A. Setiawan, “Analisis Densitas Larutan Berbasis Citra Phantom Agar dalam Kendali Mutu USG,” Positron, vol. 11, no. 1, p. 26, 2021, doi: 10.26418/positron.v11i1.44404.
Unduhan
Diterbitkan
Cara Mengutip
Terbitan
Bagian
Lisensi
Hak Cipta (c) 2025 Maulani Qonitin, Imam Tri Harsoyo, Darojat Yugiantoro, Asyrofil Ibad

Artikel ini berlisensi Creative Commons Attribution 4.0 International License.