PENGUKURAN LAJU DOSIS PAPARAN RADIASI HAMBUR PADA RUANG COMPUTER TOMOGRAPHY (CT) SCAN DI RUMAH SAKIT BHAYANGKARA MAKASSAR

  • Astuti Astuti Universitas Islam Negeri Alauddin Makassar
    (ID)
  • Sahara Sahara Universitas Islam Negeri Alauddin Makassar
    (ID)
  • Sri Zelviani Universitas Islam Negeri Alauddin Makassar
    (ID)

Abstract

This research aims to determine the effect of exposure to radiation dose on the distance from the radiation source, determine radiation dose exposure with variations in exposure factors (voltage), and to determine the radiation exposure received by workers / operators in the CT-Scan room at Bhayangkara Hospital Makassar and using a sensitive Surveymeter with variations in the exposure factor (voltage) of 100 kV, 120 kV, and 135 kV and a variation of the distance from the radiation source of 0 m, 1 m, 2 m. The results showed that the highest dose was on the front side with a voltage of 135 kV at a distance of 0 m, namely 1.5 nSv / h. While the lowest dose is on the left side with a voltage of 100 kV at a distance of 2 m, namely 0.6 nSv / h. Radiation exposure received by workers / operators in the CT-Scan room at Bhayangkara Hospital Makassar at a voltage of 135 kV, a distance of 1 m from the radiation source, namely 1.5 nSv / h. This is in accordance with the provisions of BAPATEN, namely the value of the dose received does not exceed 50 mSv in (one) year.

Downloads

Download data is not yet available.

References

Abimanyu, Adi, dkk. 2013. Modifikasi Surveymeter Dengan Penambahan Fasilitas Pesan Singkat (SMS). Batan. Yogyakarta: Seminar Nasional VIII SDM Teknik Nuklir.

Akhadi, Mukhlis. Dasar-Dasar Proteksi Radiasi. Jakarta: PT. Renika Cipta. 2000.

Bushong, S.C., 2001, Radiologic Science for Technologists, Sevent Edition, Mosby Company, Toronto.

Hanna H. Upaya Proteksi Radiasi Di Bidang Kedokteran Gigi Dengan Proyeksi Radiografi Yang Tepat. Majalah Ilmiah Kedokteran Gigi. 2006: 2(2): 75-9.

Maryanto, Djoko. 2008. Analisis Keselamatn Kerja Radiasi Pesawat Sinar-X di Unit Radiologi RSU Kota Yogyakarta. Yogyakarta: Seminar Nasional IV SDM Teknologi Nuklir.

Rasad Esjahriar. Buku Radiologi Diagnostik. Jakarta: 2005: (15-7)- (25-9).

Ruslan Hani. Ahmadi dan Riwidikno. Handoko. Fisika Kesehatan. Nuha Medika, Yogyakarta, 2007, September. 2007.

Sjahriar Rasad, Sukonto Kartoleksono, Iwan Eka uda, Radiologi Diagnostik. Balai Jakarta: FKUI. 1990

Wiryosimin, S., Mengenal Asas Proteksi Radisi. Bandung: ITB. 1995.

Yunus Barunawaty, Murtala Bachtiar. Pemanfaatan Hounsfield Unit Pada CT-Scan Dalam Menentukankepadatan Tulang Rahang Untuk Pemasangan Implan Gigi. Jurnal Dentofasial. 2010: 1

Zubaidah, A. 2005. Efek Paparan Radiasi pada Manusia. Jakarta: Badan Tenaka Nuklir.

Published
2018-12-30
How to Cite
Astuti, A., Sahara, S., & Zelviani, S. (2018). PENGUKURAN LAJU DOSIS PAPARAN RADIASI HAMBUR PADA RUANG COMPUTER TOMOGRAPHY (CT) SCAN DI RUMAH SAKIT BHAYANGKARA MAKASSAR. JFT: Jurnal Fisika Dan Terapannya, 5(2), 159-163. https://doi.org/10.24252/jft.v5i2.16110
Section
Artikel
Abstract viewed = 1102 times

Most read articles by the same author(s)

> >>